Axe-Technology

Home / Axe-Technology

Digital Control Meters

Dc Multi-Model: MMX-D
Power Meter

(Smart 485/Low Power)(48x96mm)
Accuracy 0.05% F.S.±1digitit Measuring and display DCV/DCA/W(KW)/WH(KWH) Auto range (DC0~99.99V/0~600.0V) for voltage input function Programmable rate 0 to 9999 digit (DCA/W(KW),0 to 99999999 Digits, Digit RS-485 interface

06 Channel Analog Input Panel Meter (48x96mm),

Model:MM8A
Accuracy 0.05% F.S.±1digit Measuring six channel DCA/DCV/Pt-100/Thermocouple/etc… Programmable rate -1999 to 9999 digit Input channel number(1~6) can be modified Digit RS-485 interface (Optional)

MICROPROCESS PANEL CONTROLLER METER (PUSHWHEEL
TYPE)(48x96mm),

Model: MMX-AP
Accuracy 0.1% F.S.±1digit Measuring DCA/DCV/ACA/ACV/Potentiometer/Pt-100/Transmitter/Load Cell/Resistor/ect… Programmable rate -19999 to 99999 digit Auto zero and hold function Push wheel digit switches setting easy to operate

Power Monitoring Analyzers

PLUG-IN POWER MONITOR, Model:AXE-1
Accuracy±0.1%F.S.
Measuring and display ACV/ACA/Watt/VA/Frequency/Power factor /KWH/KWH Time, ACV/ACA/Watt for ture RMS
ACA/Watt/VA/KWH/KWH time auto-range function
Over current (>15A) and over temperature(>65°C)auto-protector function , Large bright white LEDs high 16.3mm(1.146″)
Impose test Meet requirement of IEC 60950-1 6KV/3VA combination wave test Surge test (ring wave)2.5KV(0.25ms/1MHz))(IEC255-4)

MULTI-FUNCTION POWER METER ,

(96x96mm), Model:MMP-2
Accuracy ±0.25% F.S. Measuring and display ACV/ACA/Watt/Var/Power factor/Frequency/KWH/DM(Demand) Input measurement network can be selective(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Manual or auto scanning mode can be modified Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)

MULTI-FUNCTION POWER METER,

Model:MMP-3
Accuracy±0.15% F.S. Measuring ACV/ ACA/ Watt/ Var/ Power factor/Frequency/KWH) Input measurement network can be selected (1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Manual or auto scanning mode can be modified Three alarm control function (optional) Digit RS-485 interface function (Optional) CE EMC certification

Signal Transmitters

AC Current Transmitter (mini-size), Model:TWA
Accuracy ±0.025%F.S. Field-rangeable supper voltage from 14 to 30V Dimension mini-size(51.5×22.2×19.3mm) Low cost and high stability CE EMC certification

Load-cell Transmitter (Mini-size),

Model:TWL
Accuracy ±0.025%F.S. Wide selection of input range/output response time Field-rangeable supper voltage from 14 to 30V Dimension mini-size(51.5×22.2×19.3mm) Low cost and high stability CE EMC Certified

Head-mounted Two-wire Transmitter,

Model: TWP
Accuracy 0.1%F.S. Wide input ranges from 100Ω to 50KΩ(3-wire) Burnout protection function, upscale the output current limit of approximately≦20.32mA Field-rangeable supper voltage from 10 to 30V RL(max.)=(Vsupply-9V)/20mA,up to 750Ω at 24VDCLow cost and high stability CE EMC certification

Rtd (Pt-100) Isolated Transmitter, Model: TP
Accuracy 0.1% F.S. Wide selection of input/output range 3 wire configuration automatically compensateline resistance effects Wide input range for auxiliary power Dimension small and High stability CE EMC certification

Slim Type Signal Transmitters

Slim Type Ac Current/Voltage Isolated Transmitter, Model: STA
Accuracy 0.1%F.S.(TRMS),0.25%(RMS) Wide selection of input/output range Dielectric strength 1.5KVac/1 min.(input/output1/output2) Wide input range for Auxiliary Power Dimension small and High stability, CE EMC Certification

Slim Type Load-cell Isolated Transmitter,

Model: STL
Accuracy 0.1% F.S. Wide selection of input/output range Dielectric strength 1.5KVac/1 min.(input/output1/output2) Wide input range for auxiliary power Dimension small and High stability CE EMC certification

Slim Type Frequency Isolated Transmitter,

Model: STF
Accuracy 0.1% F.S. Wide selection of input/output range Dielectric strength 1.5KVac/1 min.(input/output1/output2) Wide input range for auxiliary power Dimension small & High stability CE EMC certification

Power Transducers

AC Current & Voltage Transducer, Model: PA
Accuracy 0.1% F.S.(TRMS),0.25% F.S.(RMS) Wide selection of Input/output range Dielectric strength 2KVac/1min(input/output/power) Impuse test 5KV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave)2.5KV (0.25ms/1MHz) (IEC255-4) Dimension small and High stability CE EMC certification

AC Frequency Transducer,

Model: PF
Accuracy 0.05% F.S. Wide selection of input/output range Dielectric strength 2KVac/1min(input/output/power) Impuse test 5KV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave)2.5KV (0.25ms/1MHz)(IEC255-4) Dimension small and High stability CE EMC certification

AC Watt & Var Transducer,

Model: PW
Accuracy 0.25% F.S. Wide Selection of input/output range
Dielectric strength 2KVac/1min(input/output/power) Impuse test 5kV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave) 2.5KV (0.25ms/1MHz) (IEC255-4) Dimension small and High Stability

AC WATTHOUR & VARHOUR TRANSDUCER,

Model: PWH
Accuracy 0.25% F.S. Wide Selection of input/output range Dielectric strength 2KVac/1min(input/output/power) Impuse test 5KV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave)2.5KV (0.25ms/1MHz) (IEC255-4) Dimension small and High stability

AC Watt/ Watthour & Var/ Varhour Transducer,

Model: PWWH
Accuracy 0.25% F.S. Wide selection of input/output range Dielectric strength 2KVac/1min(input/output/power) Impuse test 5KV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave)2.5KV (0.25ms/1MHz) (IEC255-4) Dimension small and High stability CE EMC certification

AC Power Factor (Cosø) Transducer,

Model: PPF
Accuracy 0.25% F.S.±0.25° Wide Selection of input/output range Dielectric strength 2KVac/1min(input/output/power) Impuse test 5KV (1.2x50us)(IEC255-4,ANSI C37.90a/1974) Surge test (ring wave)2.5KV (0.25ms/1MHz) (IEC255-4) Dimension small and High stability

Microprocess Frequency Isolated Transmitter,

Model: TMF
Accuracy 0.03% F.S. Input range from 0.01 Hz to 80 KHz 15 bit DAC isolating analog output Dielectric strength 2KVac/1min(input/output/power), Wide input range for auxiliary power, Dimension small and High stability